1 / 2
Descrição do produto
DCVOLTAGE |
5V |
|
LED OPERATION VOLTAGE |
3~5V |
|
RATEDCURRENT |
5A |
|
CURRENTRANGE |
0~5A |
|
RATEDPOWER |
25W |
|
RIPPLE&NOISENOTE.2 |
80MVP-P |
|
VOLTAGE ADJ RANGE |
4.5~5.5V |
|
Can be adjusted by intemal potential meter SVR2 | ||
VOLTAGETOLERANCENOTE.3 |
±5.0% |
|
LINEREGULATION |
±1.0% |
|
LOADREGULATION |
±2.0% |
|
SETUP.RISEHOLD.TIME |
500ms, 80ms/230VAC 1000ms / 115VAC at full load |
|
HOLD UP TIME(TYP) |
50ms /230VAC 16ms/115VAC at full load |
|
INPUT |
VOLTAGERANGE |
90~264VAC |
FREQUENCYRANGE |
47~63HZ |
|
EFFICIENCY |
75% |
|
AC CURRENT |
0.75A/115VAC 0.48A/230VAC |
|
INRUSH CURRENT |
Cold start 60A/230vac |
|
LEAKAGECURRENT |
0.25mA/240VAC |
|
PROTECTION |
OVER CURRENT |
95~110% |
Protection typeConstant current limiting,recovers automatically after fault condition is removed | ||
OVER VOLTAGE |
5.75~6.75V |
|
Protection typeShut down o/p voltage,re-power on to recover. | ||
FUNCTION |
DIMMING CONTROL (OPTIONAL) |
1~10VDC or PWM |
ENVIRONMENT |
WORKINGTIMP |
-20~+60(refer to output load derating curve) |
WORKINGHUMIDITY |
-20~90%Rhnon-condensing |
|
STORAGE TEMP HUMIDITY |
-40~+80 10~95%RH |
|
TEMPCOEFFICIENT |
±0.03%(0~50) |
|
VIBRATION |
10~500HZ,2G10min/1cycle period for 60 min each alongX,Y,Zaxes |
|
SAFETY&EMC |
SAFETYSTANDARDS |
Design refer to UL1310 Class 2,TUV EN60950-1,EN61347-2-13,CAN/CSA C22.2 NO.223-M91M,IP67 approved |
WITHSTAND VOLTAGE |
1/P-0/P:3KVAC |
|
ISOLATIONRESISTANCE |
1/P-0/P:>100M Ohms/500VDC/25/70%RH |
|
EMI CONDUCTICN&
RADIATION
|
Compliance to EN55022(CISPR22)classB |
|
HARMONICCURRENT |
Compliance to EN61000-3-2,-3 |
|
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204,EN50204,EN61000-6-1 Light industry level criteriaA |
|
QTHERS |
MTBF |
628.3Khrs min MIL-HDBK-217F(25) |
DIMENSION |
145*47*30mm(L*W*H) |
|
PACKING |
0.26Kg 60pcs / 16.6Kg / 1.25CUFT |
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.Derating may be needed under low input voltage.please check the derating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meet EMC directives.
6.Length of set up time is measured at first.tuming ON/OFF the power supply may lead to increase of the set up time .
7.Constant current operation region is within the specified output voltage above. This is suitable operation region for LED related applications
|
Envie sua pergunta a este fornecedor